5.1 Moisture

There are two types of humidity settings:

1. humidity setting:

  • Set the desired maximum relative humidity in .
    The dehumidifier dehumidifies as long as the moisture content is above the set value.
    Hystersen is +- 2.

From software version 1.3.0 the hysteresis is adjustable!

  • Constantly on.
    Dehumidification is constantly taking place.
  • Constantly off.
    Dehumidification never starts.

2. humidity control:

  • RF.
    Dehumidification starts when the relative humidity of the air exceeds the set value.
  • RF + Temp.
    Dehumidification starts when the relative humidity of the air exceeds the set value at temperatures above +15°C.
    The moisture content is allowed to rise by 1%/°C at temperatures below +15°C before dehumidification starts.
    The function is only active in the temperature range 0-15°C.